Determination of Decabrominated Diphenyl Ether in Electronic and Electrical Equipments with ASE-HPLC/UV

黄英,杭义萍
DOI: https://doi.org/10.3969/j.issn.1000-0720.2009.01.024
2009-01-01
Abstract:A rapid,simple and reliable method was described for extraction,purification and quantitative determina- tion of decabrominated diphenyl ether in electronic and electrical equipments.Extraction was carried out using acceler- ated solvent extra■n (ASE).The further purification was done on a pasteur pipette.LC separation was achieved us- ing a reversed-phase C_(18) column and a mixture of water and methanol with ultraviolet detection.Recovery is 86.6%, and RSD is less than 5 %.The detection limit is 0.5 mg/L.