A Ubbelodhe Viscometer withPolytetrafluoroethylene Capillary

蔡佳利,薄淑琴,秦汶,严小虎,程镕时
DOI: https://doi.org/10.3969/j.issn.1000-0518.2001.05.020
2001-01-01
Abstract:A modified Ubbelodhe viscometer with polytetrafluoroethylene capillary has beenfabricated. The newly constructed viscometer was tested and compared with conventional glassviscometer by measuring the aqueous solution viscosity of a partially hydrolyzed polyacrylamidesample covering a considerable wide concentration range down to extremely dilute region. Theinterference from polymer adsorption onto the capillary inner wall surface on the viscositymeasurements is completely avoided when the new modified viscosimeter is used instead of commonglass viscometer. The experimental results indicate that the so called “polyelectrolyte effect” ofsolution viscosity is just only an apparent phenomenon due to polymer adsorption.
What problem does this paper attempt to address?