Anti-progressive collapse performance analysis of different configurations ring plate connection between concrete-filled steel tubular column and H-steel beam

Yanli SHI,Tianhao LI,Wenda WANG
DOI: https://doi.org/10.13577/j.jnd.2017.0304
2017-01-01
Abstract:In this paper,the finite element analysis software ABAQUS was used to simulate the progressive collapse process of concrete-filled steel tubular column to H-steel beam with ring plate connections under the failure condition of the middle column.It was considered that the konstructional change of three parts of the ring plate,steel beam and the joint core area has great influence on the resistance to the progressive collapse of the connections.The research shows that the ring plate extended size may affect the position of plastic hinge,but its effect on performance of the progressive collapse is not obvious,therefor,the selection of the ring plate should fully consider the structure,procedure and economic needs.The structure of steel beam influences giving play to catenary action.In the design of anti-progressive collapse,extended wing connection is recommended for use and flange weakened connection is not recommended to be used.In the case of insufficient headroom,the connection with openings on beam webs may be used.The constructional mode of core area of the connection may affect the brittle failure of the weld.In the design,the haunch enhanced connection is recommended to be used.When the existing building is reinforced,weld of horizontal reinforced rib or open corblel is suggested,this method may greatly enhance progressive collapse-resisting ability of existing structure.
What problem does this paper attempt to address?