Automatic Pretreatment and Determination of Organophosphorus Flame Retardants in Freshwater Fish Samples by Gas Chromatography Tandem Mass Spectrometry

Ying Zhang,Lifei Wei,Shengyu Liu,Wei Liu,Xinyu Liu,Yi Li
DOI: https://doi.org/10.7524/AJE.1673-5897.20170114009
2017-01-01
Asian Journal of Ecotoxicology
Abstract:An analytical method for the determination of 10 organophosphorus flame retardants (OPFRs) in freshwater fish samples was developed using automated equipment for pretreatment and gas chromatography-tandem mass spectrometry (GC-MS/MS) for quantification.In the present method,the samples were extracted using automatic soxhlet extraction system,and then a two-step clean-up (including automatic gel permeation chromatography (GPC) and florisil) was used to purify the extract.Finally,the GC-MS/MS was used for qualitation and quantitation by multi-reaction monitoring (MRM) mode.Experimental results showed that the best collection time of the automatic GPC system was from 900 to 1 680 seconds using ethyl acetate and hexane mixture (1∶1,V/V) as mobile phase at a flow rate of 5.0 mL·min-1.The method detection limits ranged from 0.002 ng·g-1 to 0.192 ng·g-1 wet weight,and the recoveries were in the range of 48.7%-122%,with relative standard deviations (RSDs) of less than 10% except for triethylphosphate (TEP) (17.7%) and tris(1,3-dichloropropyl) phosphate (TDCP) (11.9%).The developed method was applied to determine the OPFRs in freshwater fish collected from an outlet of a sewage treatment plant in the East River.The recoveries of d27-TBP spiked in the samples ranged from 82.4% to 114%,and the total concentrations of OPFRs in the samples ranged from not detected to 6.41 ng·g-1 wet weight.
What problem does this paper attempt to address?