Evaluation of Biological Safety of Carbon-Fibre Reinforced Resin Compound

Li LIU,Yan GAO,Lie-fen ZHANG
DOI: https://doi.org/10.3969/j.issn.1001-7119.2005.06.012
2005-01-01
Abstract:Purpose To evaluate the biological safety of carbon-fibre reinforced composite as a dental material and provide the evidence before clinical applicati on.Methods Three tests were chosen in this study,namely short-term systemic tox icity(oral route),acute systemic toxicity test(introvenous route) and haemolys is test.Results Test 1.None of the rats was abnormal,there was no significant differencs in utility rate of forage and relative rising rate of weight between the experimental group ang control group(P0.05).The internal organs had no pat hological change.Test 2.All mice had no toxic sign,there was no significant difference in the change of weight between the experiment group and control group( P0.05).No pathological change was found in the internal organs.Test 3.Acute ha emolysis rate in vitro of the material was 2%.Conclusion Carbon-fibre reinforced resin compound had no acute systemic toxic action on animals and haemolysis effect in vitro.
What problem does this paper attempt to address?