The pool boiling heat transfer characteristics of the surface modified copper square pillar arrays

Shuai MOU,Guanxi HU,Zhiguo XU,Changying ZHAO
DOI: https://doi.org/10.3969/j.issn.2095-2783.2018.18.016
2018-01-01
Abstract:By means of chemical deposition, the surface of copper square pillar arrays and gradient square pillar arrays are plated with silver to change their wettability, and then the effects of morphology, surface wettability and surfactant on the heat transfer properties of boiling are studied.The experimental results show that the heat transfer performance of the copper square pillar arrays becomes worse after deposition.For the gradient square pillar arrays, due to the fact that the bubble is easy to merge, agas film is formed locally on the surface, which hinders the replenishment of surrounding water and further weakens the heat transfer.After adding the isopropanol and n-heptanol, the surface tension of the liquid will decrease.At low heat flux, the number of vaporization cores and bubble volume both decrease, thereby leading to the decreased boiling heat transfer capacity.When heat flux q= 66.12kW/m2, the heat transfer coefficient will decrease with the increasement of concentration.At high heat flux, the addition of isopropanol or n-heptanol can effectively prevent the formation of gas film on the heating surface, so the heat transfer capacity gradually increases with the increasement of concentration.