Pool boiling heat transfer performance and mechanism of square copper pillar arrays with partially-modified surface

Shuai MOU,Changying ZHAO,Zhiguo XU
DOI: https://doi.org/10.11949/j.issn.0438?1157.20181070
2019-01-01
Abstract:In the present study, the effects of wettability, surface topography and surfactant on the growth of bubbles and pool boiling heat transfer of straight and gradient square copper pillar arrays with partially-modified surface were investigated. The experimental medium was deionized water, 100, 200, 400, 800 mg·L-1 in isopropanol solution and n-heptanol solution. The results showed that silver deposition on square copper pillar decreases the wettability, and increases bubble number. Addition of isopropanol or n-heptanol into deionized water decreases the number and departure diameter of bubbles in the heat flux range of 66.1—202 kW·m-2. However, when the heat flux increases to 413 kW·m-2, the surfactant can effectively prevent bubbles from merging, so the boiling heat transfer coefficient of the pool boiling decreases first and then increases with the increase of the concentration. The gradient square pillar structure with upper and lower layers of 0.5 mm and 1mm and a spacing of 2 mm promotes the coalescence of bubbles and formation of a gas film on the heating surface, and then worsens pool boiling heat transfer.
What problem does this paper attempt to address?