Structure and hemocompatibility of nitrided 316L stainless steel

Difeng LUO,Fan ZHANG,Tao FU,Shenglan HAN,Feng WU
DOI: https://doi.org/10.19529/j.cnki.1672-6278.2018.02.14
2018-01-01
Journal of Biomedical Engineering Research
Abstract:The structure and properties of plasma nitrided 316L stainless steel were studied in comparison with the polished sample and the sol-gel TiO2coated sample.The polished stainless steel sheet was treated with TiO 2coating by dip coating method,and the polished stainless steel sheet after sputtering was treated by nitriding plasma.The TiO2film did not obviously change surface morpholo-gy of stainless steel substrate,but it had fine cracks with the width of about 1 μm.Martensite diffraction peaks were also detected for the coating sample.The plasma nitrided sample was rough,and only the expanded austenite (S phase) was detected at the surface. Compared with the polished and the TiO 2coated samples, the nitrided sample was more hydrophilic (contact angle ~70o), with the dominant polar component of surface energy (86%).The nitrided sample had lower interfacial tensions towards water,blood and fi-brinogen, but larger one towards albumin.The potentiodynamic polarization test showed that the nitrided sample had the best corrosion resistance.The three materials meet the hemolysis requirement for medical implants (<5%), and the nitrided sample has the best an-ti-platelet aggregating function.
What problem does this paper attempt to address?