Clinical Effi cacy of the Treatment of Acute Achilles Tendon Rupture with Achillon Device

Min-feng GAN,Jun ZOU,Hong-tao ZHANG,Ming XU,Jian LU,Hui-lin YANG
DOI: https://doi.org/10.3969/j.issn.1009-881X.2015.03.023
2015-01-01
Abstract:ObjectiveTo evaluate the clinical efficacy of Achillon device in treatment of acute Achilles tendon rupture (AATR).MethodsFrom Jan 2012 to Dec 2013, 23 patients with AATR were treated with Achillon device. There were 22 males and 1 female, with the average age of 34.1 years (20 to 48 years). The results of Thompson test were positive in all cases. Postoperative complications were surveyed during the follow-up. The ankle joint function was evaluated at final follow-up according to the American Orthopaedic Foot and Ankle Society (AOFAS) standards.ResultsAll the 23 patients were followed up, and the duration ranged from 12 to 24 months. There were no wound infections, recurrent rupture, or sural nerve complications. At thefi nal follow-up, the mean AOFAS score was 93.5 (89 to 98).Conclusion It is effective and safe that the Achillon device is used to repair the acute Achilles tendon ruptures with low incidence of complications.