The Effect of Viscoelastic Sponge Mattress Combined with Turning Over during Preventing Pressure Ulcer for Critical Care Patients

Qi-xia JIANG,Guo-hong LI,Hai-ying LIU,Jing JIA,Ya-jun ZHU,Yi ZHOU,Yun-juan HUANG,Ya-hong LIU,Jie-mei FAN,Zhi-qiang WENG
DOI: https://doi.org/10.16460/j.issn1008-9969.2017.14.062
2017-01-01
Journal of Nursing
Abstract:Objective To compare the efficacy and comfortability of 2 off-loading pressure programs in preventing pressure ulcers for critical care patients. Methods Totally 1,194 patients were randomly divided into trail group(n=596)and control group(n=598) with stratified blocked randomization method. A viscoelastic sponge mattress was used combined with turning over every four hours for 7ds in trial group and a low-air loss mattress combined with turning over every two hours for 7ds in control group. The incidence of pressure ulcer and patients' comfortability were compared. Results There were 2 and 11 cases of pressure ulcer in trial group and control group respectively, with an incidence rate of 0.3%and 1.8%respectively. The difference between the two groups was statistically significant (x2=6.629, P=0.012). Patients in trial group felt more comfortable than those in control group (F=26.440, P<0.001). Conclusion Viscoelastic sponge mattress combined with turning over every four hours is more beneficial to improving patients ' comfortability and the incidence of pressure ulcer for critical patients in ICU.
What problem does this paper attempt to address?