Application of water consumption control in Volumetric modulated arc therapy for cervical cancer

陈吉祥,李小凡,李修伍,杨敬贤
DOI: https://doi.org/10.3969/j.issn.1671-4695.2015.011.023
2015-01-01
Abstract:Objective To investigate water consumption control in increacing accuracy of radiotherapy and decreacing incidence of cystitis an proctitis of cervical cancer patients. Methods 126 cases of advanced cervical cancer patients were randomly divided into two group,observa-tion group and control group,63 cases in each group. The two group undertook external irradiation and after-loading therapy were recruited into our study. The observation group after emptying of bladder,taking 500 ml water,these patients undertook therapy in an hour. The control group before treatment patients were asked to self holding back. Precision radiotherapy,put a bit error occurrence and complications were observed. Re-sults The observation and control group of bladder volume consistent with radiotherapy accuracy were 95. 7% and 93. 3% for first time. Setup er-rors in control group in both X axis and Y axis direction was larger than those in control group( P <0. 05),and the differences in the Z axis were not statistically significant between two groups( P >0. 05). Incidence rate of radiation proctitis and radiocystitis showed significant difference be-tween the two groups. Conclusion VMAT employed in radiotherapy for cervical cancer combined with water consumption control could achieve well accuracy of radiotherapy,decrease incidence of cystitis and improve prognosis of cervical cancer patients.
What problem does this paper attempt to address?