Urinary Stone Composition Analysis Using Dual Source CT Dual Energy Imaging

Xianchun ZENG,Jie JIANG,Li WU,Xunran ZHAO,Dan HAN
DOI: https://doi.org/10.3969/j.issn.1005-5185.2015.02.004
2015-01-01
Abstract:PurposeTo analyze the urinary stone chemical composition using dual source CT (DSCT) dual energy imaging.Materials and MethodsNinety-seven stone samples with known chemical composition were placed in fresh swine kidneys and examined with DSCT dual energy scan, including 55 calcium oxalate stones, 13 hydroxyapatite stones, 9 uric acid stones, 4 cystine stones, 2 struvite stones and 14 mixed stones. The mean attenuation values and dual energy index (DEI) were measured at 80 kV and 140 kV. The stone composition was analyzed to determine the sensitivity, specificity and accuracy.ResultsDual energy analysis showed 59 calcium oxalate stones, 11 hydroxyapatite stones, 9 uric acid stones, 4 cystine stones and 14 mixed stones. 2 hydroxyapatite stones were erroneously marked as calcium oxalate stones and 2 struvite stones as calcium oxalate stones. The accuracy was 95.88% (93/97). The difference CT value at 80 kV and 140 kV and DEI value were statistically significant (P<0.05). The sensitivity for detecting calcium oxalate stones, hydroxyapatite stones, uric acid stones and cysteine stones were 100.00%, 84.60%, 100.00% and 100.00%, respectively; with specificity of 85.70%, 100.00%, 100.00% and 100.00%, respectively; and the accuracy were 95.18%, 97.59%, 100.00% and 100.00%, respectively.ConclusionDSCT dual energy imaging accurately analyzes the chemical composition of urinary stone in vitro, which provides important clinical value in analyzing the urinary stonesin vivo.
What problem does this paper attempt to address?