Comparative Study of ARFI and RTE Technique in Evaluating Liver Stiffness in Children with Biliary Atresia

Guoying Zhang,Ying Tang,Ningning Niu,Hongtao Wu,Mulei Yang,Yang Liu
DOI: https://doi.org/10.3969/j.issn.1002-0101.2018.03.019
2018-01-01
Abstract:Objective Comparatively analysing the evaluating value of acoustic radiation force impulse elastography (ARFI) and real-time tissue elastography (RTE) for liver stiffness of patients with biliary atresia (BA).Methods 45 patients with BA were collected from in Tianjin First Central Hospital.ARFI and RTE were used to measure the stiffness of the liver,expressed as ARFI value and MEAN value.30 healthy volunteer children as control.The ROC curve was used to evaluate the detection value.Recording the serum liver function index of each patients,calculating the correlation between each other.Results The ARFI value of patients with BA was significantly higher than that of control group,The MEAN value was lower,differences had statistical significance (P< 0.01);Analysed by ROC curve,the biggest area under the ROC curve,sensitivity,and specificity of the ARFI value,MEAN value to evaluate the liver stiffness were 0.99,97.8 %,100 % and 0.88,100 %,80 %,respectively.The correlation between ARFI value and AST,TBIL,DBIL,IBIL was positive,and ALB,GGT was negative (All P<0.05).Whereas,the MEAN value was only negatively correlated with DBIL (P<0.05).Conclusions The evaluating value of ARFI and RTE for liver stiffness of BA were similar high.Compare with each other,the sensitivity was similarly,but the specificity and accuracy of ARFI were better than RTE,and ARFI has good correlation with liver function.