Experimental Study on Contrast-enhanced Ultrasound of the Rabbit Renal Ischemia-reperfusion Injury

姚洁洁,詹维伟,陈曼,周建桥,陈林,刘振华
DOI: https://doi.org/10.3969/j.issn.1002-0101.2010.01.004
2010-01-01
Abstract:Objective To evaluate the diagnostic value of gray-scale contrast-enhanced ultrasonography (CEUS) and quantitative analysis technology in the rabbit renal ischemia-reperfusion injury(IRI).Methods The rabbit model of renal IRI was estabilished.Fifteen New Zealand rabbits were divided into before surgery I_0 group,and different ischemic time (I_1-I_3) group.CEUS was used to observe the pattern of renal perfusion and perfusion peak time(TP),amplitude of peak intensity (A),curve rising slope rate (β)and area under the curve (AUC) were analysed.Results With the ischemic time increasing,CEUS showed that renal cortical perfusion echo gradually became weaker,perfusion parameter values showed increased TP,decreased β,AUC first increasing and then decreasing and A has no significant change.Compared with the normal group, TP、 AUC、β and A were all significantly different.Conclusions The CEUS and quantitative analysis technology can determine the varying degrees of renal IRI non-invasively.