Microvascular Flow Imaging Evaluation of Renal Trauma: an Experimental Animal Study
马骏,王月香,罗渝昆,高菡静,孟祥宇,费翔,肖静,李文
DOI: https://doi.org/10.3877/cma.j.issn.1672-6448.2022.09.021
2022-01-01
Abstract:Objective:To observe the changes of traumatic lesions and renal microcirculatory system in experimental animals with different degrees of renal trauma by microvascular flow imaging (MV-Flow).Methods:Fifteen New Zealand white rabbits were divided into three groups (10 control kidneys and 10 injured kidneys in each group) according to the degree of trauma. After a laparotomy was performed, the MV-Flow images of normal kidneys were observed, and the normal cortical vascular index (VI) was measured as a control. Thirty minutes after the model was established, the kidneys were examined by conventional two-dimensional ultrasound and MV-Flow imaging, and the VI of traumatic lesions was measured. Finally, the rabbits were killed, and their kidneys were removed to prepare gross specimens. The Wilcoxon test was used to compare the data between the experimental group and control group, and the Kruskal-Wallis H test was used for comparison among the experimental groups.Results:MV-Flow imaging clearly displayed renal segmental blood vessels, arcuate blood vessels, and interlobular blood vessels (full of cortex). After trauma, there were partial defects in the blood flow signal in the area of the traumatic lesion, with "worm-like" or "slit-like" defects according to different trauma grades, indicating the presence of trauma in the area. The median VI values of the three groups (control group vs trauma group) were 96.3% (85.01%, 96.1%) vs 2.21% (1.09%, 3.16%), 91.71% (85.68%, 93.94%) vs 1.81% (1.24%, 5.60%) ,and 92.45% (85.70%, 95.25%) vs 1.95% (0.67%, 5.43%), respectively. The data of each group showed a non-normal distribution and the differences were statistically significant (Z=-2.803, P=0.005), suggesting that there was a significant difference between the VI values of normal cortex and traumatic lesion. There was no significant difference in VI among the three experimental groups, which indicated that there was no significant difference in VI values among different severity of traumatic lesions (H=0.025, P=0.987).Conclusion:After renal trauma, MV-Flow imaging can show "worm-like" or "slit-like" defects in renal cortical vessels, and the VI value is close to 1%. MV-Flow imaging can accurately show renal traumatic lesions by monitoring the change of microcirculation of the kidneys, which indicates the presence of renal trauma.