Application of Cryoballoon Ablation in Patients with Paroxysmal Atrial Fibrillation

凌天佑,潘文麒,金奇,张凝,罗庆志,韩岩新,王义龙,吴立群
DOI: https://doi.org/10.3760/cma.j.issn.1007-6638.2015.02.010
2015-01-01
Abstract:Objective To evaluate the application of cryoballoon-based ablation in paroxysmal atrial fibrillation (AF) patients.Methods A total of 107 patients with paroxysmal AF,who underwent cryoballoon ablation,were enrolled in the study.They were followed up at three months and six months after ablation.Results One hundred and six patients (99.1%)achieved three or more pulmonary vein(PV) isolation and 97.2% patients achieved isolation of all four PV.Ischemic stroke and arterio-venous fistula were observed in one patient respectively.Two patients had phrenic nerve palsy.At six months follow-up,86.0% patients were free of AF.Patients without AF recurrence in the first three days after ablation procedure had a higher rate of sinus rhythm compared with the patients who had AF recurrence in the first three days (94.4% vs.64.3%,P=0.021).Conclusion Cryoballoon ablation can be effectively and safely used in paroxysmal AF patients.