Effect of Carbon Dioxide Pneumoperitoneum and Trendelenburg Position on the Cerebral Artery Blood Flow During Laparoscopic Surgery in Patients Over 60 Years Old

李岩,王春艺,李刚,郭向阳
DOI: https://doi.org/10.3969/j.issn.1009-6604.2017.07.003
2017-01-01
Abstract:Objective To evaluate the effect of carbon dioxide pneumoperitoneum and Trendelenburg position on the cerebral artery blood flow during laparoscopic surgery in patients over 60 years old.Methods One hundred elderly patients, ASA physical status Ⅰ-Ⅱ, aged ≥60 years, with operating time > 2 h of elective laparoscopic surgery, were assigned into two groups according to patient''s age (n=50 each): patients aged 60-70 years were enrolled in group A and patients aged 70 years or older in group B.For all the patients, blood flow signals of right middle cerebral artery were detected by transcranial Doppler and systolic blood flow velocity (Vs), mean blood flow velocity (Vm), and pulsatility index (PI) were recorded at baseline before anesthesia induction (T0), 5 min after endotracheal intubation (T1), after pneumoperitoneum achieved (T2), immediately, 1 h, and 2 h after Trendelenberg position (T3, T4, and T5, respectively), and 10 min in supine position after termination of pneumoperitoneum (T6).The mean arterial pressure (MAP) was also recorded at each time-point.Results In group A, the values of Vs from T4 to T6 were (73.1±10.8), (73.5±9.9), (77.5±10.9) cm/s, respectively, which were much faster than that at T1 (66.4±9.3) cm/s (P<0.05).Similarly, the values of Vm from T3 to T6 were (55.3±7.9), (54.5±9.2), (57.3±10.1), (68.9±9.9) cm/s, respectively, which were much faster than that at T1 (48.3±8.1) cm/s (P<0.05).In group B, the values of Vs from T3 to T6 were (74.4±9.5), (78.2±9.5), (79.0±10.3), and (82.0±9.3) cm/s, respectively, all of which were much faster than that at T1 (65.8±8.9) cm/s (P<0.05).Similarly, the values of Vm from T2 to T6 were (55.2±7.6), (59.3±9.5), (59.2±8.7), (61.6±10.2), and (67.6±8.8) cm/s, respectively, all of which were much faster than that at T1 (46.5±8.9) cm/s (P<0.05).The values of Vs, Vm at T2-T5 were much faster in group B than those in group A (P<0.05).While the values of PI at T3-T6 were much faster in group B than those in group A (P<0.05).There was no significant difference in MAP between the two groups (P>0.05).Conclusions Trendelenburg position at 30° cause increased cerebral blood backflow in elderly patients during laparoscopic surgery.With the increase of age, the impact of pneumoperitoneum and Trendelenburg position on cerebral blood flow is more obvious.
What problem does this paper attempt to address?