Effects of Computer Assisted Minimally Invasive Surgery on Blood Loss after Total Knee Replacement

李锋,林雪林,张克,刘延青,刘岩,田华
DOI: https://doi.org/10.3969/j.issn.1009-6604.2015.03.002
2015-01-01
Abstract:Objective To evaluate the impact of minimally invasive technique ( MIS ) using a navigation system on postoperative blood loss in total knee arthroplasty ( TKA ) . Methods We compared the total blood volume loss in a cohort of patients with osteoarthritis undergoing either computer navigated minimally invasive technique ( n =40 ) or standard intramedullary technique (n=40).The total and hidden blood loss was calculated according to the Ward and the Gross method. Results The total blood loss was significantly less in the computer assisted group ( 1025 ±184 ) ml as compared with the conventional group (1494 ±201) ml (t=10.885, P=0.000).Patients with a computer navigated procedure and MIS technique had a significantly less dominant blood loss [(621 ±188) ml vs.(724 ±197) ml, t=2.392, P=0.019] and hidden blood loss [(404 ±179) ml vs. (732 ±204) ml,t=7.644,P=0.000] as compared with those who underwent a conventional TKA.The blood transfusion rate was 12.5%( 5/40 ) in the computer assisted group and 30.0% ( 12/40 ) in the conventional group, without statistically significant difference (χ2 =3.660, P=0.056).The deep vein thrombosis rate was 25.0%(10/40) in the computer assisted group and 42.5%(17/40 ) in the conventional group, without statistically significant difference (χ2 =2.739, P=0.098). Conclusion Computer navigated TKA combined with MIS technique has benefits of reduced postoperative blood loss, lower blood transfusion and deep vein thrombosis rate.
What problem does this paper attempt to address?