Anatomy Study of Five Methods of Sacral Screw Fixation

严军,郭春,唐天驷,杨惠林
DOI: https://doi.org/10.3969/j.issn.1672-9935.2001.02.013
2001-01-01
Abstract:Objective To evaluate the safety of five methods of sacral screw fixation. Methods To anatomize seven bodies and use kwires imitating five methods of sacral screw fixation, the k-wires penetrate the anterior wall of sacrum, the possibility of damage to the structures anterior to sacrum, the range of the safe zone of sacrum, the length of screws has been gauged and evaluated. Results Pedical transvertebral screw (PTSF for short) should not penetrate the anterior L5 vertebral body cortes, S1 screws with the directions vertical of anterolateral to the iliac wing have a tendency to injury internal iliac vessels and lumbosacral trunk, S1 screw which aims at sacral promontory is dangerous to middle sacral vessels, S2 screw would damage anterior ramus of first sacral nerve and sympatheti trunk. Conclusion All five methods of sacral screw can injuruy important structures anterior to sacrum. Attention should be payed while oprative procedure
What problem does this paper attempt to address?