A preliminary study on the application of augmented reality technique based on Sina in the localization of spinal canal tumors

韩芸峰,杨军
DOI: https://doi.org/10.3760/cma.j.cn112050-20200312-00120
2020-01-01
Abstract:Objective:To explore the application value of augmented reality based on Sina in the localization of spinal canal tumors.Methods:The clinical data of 20 patients with spinal canal tumors who underwent surgical treatment at Neurosurgery Department of Peking University Third Hospital from January 2019 to December 2019 were retrospectively analyzed. S-group (based on Sina, 10 cases) and A-group (based on anatomical markers, 10 cases) were randomly divided. Before surgery, the skin projection of tumor was located in both groups. Augmented reality method based on Sina was applied in S-group, while the anatomical markers on the body surface were the only references in A-group. The localization results of the two groups were verified using intraoperative C-arm and compared with the actual location of the tumor shown on MRI. The deviation, total localization time and times of C-arm used were documented and compared between two groups.Results:The total localization time in S-group (12.5±3.0 min) was longer than that in A-group (9.3±1.7 min) ( t=2.913, P=0.009). The localization deviation in S-group (2.98±0.92 cm) was significantly less than that in A-group (4.39±1.87 cm) ( t=-2.131, P=0.047), and times of C-arm used (1.3±0.5) in S-group was less than that in A-group (2.2±0.8) ( t=-3.077, P=0.006). Conclusions:It is safe and precise to localize spinal canal tumor using augmented reality based on Sina. However, the accuracy of Sina needs further verification by more clinical practice.
What problem does this paper attempt to address?