The Study of Ion Diffusion on the Interface of Homemade Pure Titanium Implant-Bone Tissue

邹丽剑,张涤生,王炜,朱昌,张仁俊,李越生
DOI: https://doi.org/10.3760/j.issn:1009-4598.2001.04.015
2001-01-01
Abstract:Objective This study was to investigate the ion diffusion and its influence of pure titanium implant. Methods A comparative study was taken on diffusion and distribution of Ti +, Ca 2+ , P -, etc. of homemade pure titanium implant at different period using SEM EDA, EDAX, and TOF SIMS. Results The Ti + density within 3 μm to the interface was very high. With the distance to the interface increasing the density became lower until to almost zero at 100μm. While Ti + diffused into the bone tissue, Ca 2+ , P -, Na +, K + etc. in the bone dispersed into the titanium material. The diffusion of Ti + did not cause inflammation, toxicity and anaphylaxis of the contact tissue. Conclusions The element distribution change in the bone tissue contacting titanium implant and the oxide layer showed that titanium was involved in the procedure of biochemistry reaction. The physical and chemical reaction occurred between titanium and bone tissue.