Intraoperative Ultrasound in Minimally Invasive Miccili Surgery for Multiple Thyroid Tumors

伍波,樊友本,郭伯敏,康杰
DOI: https://doi.org/10.3760/cma.j.issn.1674-6090.2010.02.008
2010-01-01
Abstract:Objective To evaluate the significance of intaoperative ultrasound examination for minimal invasive video-assisted thyroidectomy.Methods The clinical data of 48 cases with multiple thyroid tumors in our hospital from Jun 2007 to Jan 2009 were studied.The intraoperative ultrasound examination was performed during minimal invasive video-assisted thyroidectomy.Results The average incision length of 48 patients were 2.0 cm.Only one case was converted due to thyroid papillary carcinoma diagnosed by intraoperative ultrasonography.3 patients underwent unilateral thyroid lobectomy due to intraoperative frozen-section examination unable to confirm benign or malignant.Others thyroid lesions were only resected or associated with a small amount of lobe tissues.The maximum diameter of thyroid lesions was 0.4 cm to 5.0 cm,an average of 1.6 cm.One case hypocalcemia was found after operation.During a follow-up time of 6 months to 18 months,one case of thyroid cancer needed to take 150 μg euthyrox.Two cases of Hashimoto's thyroiditis needed to take a small dose of thyroxine replacement therapy.The rest patients'thyroid hormones were normal.Conclusions Intraoperative ultrasonic examination in minimal invasive video-assisted thyroidectomy for multiple thyroid tumor makes the surgery more accurate,avoids intraoperative injury and prevents omission of thyroid nodes.
What problem does this paper attempt to address?