Target correction based on electrode deviation in deep brain stimulation: a preliminary study
朱君明,傅伟明,张建民,蒋鸿杰,郑喆,罗巍
DOI: https://doi.org/10.3760/cma.j.cn112050-20200310-00115
2021-01-01
Abstract:Objective:To investigate the application of target correction method based on electrode deviation in deep brain stimulation (DBS), so as to determine whether target correction could improve the accuracy of electrode implantation.Methods:Sixty-one Parkinson′s disease patients treated with subthalamic DBS from March 2014 to April 2018 at Neurosurgery Department, the Second Affiliated Hospital of Zhejiang University School of Medicine were retrospectively included. Among those patients, 42 patients (84 electrodes) who underwent DBS from March 2014 to March 2017 were categorized into the uncorrected group. After operation, MRI/CT fusion was performed. Formulas were used to calculate the overall deviation of the electrodes ( ΔP) and directional deviation on the X, Y and Z axes. Target correction rules were made based on the deviation of electrodes. Nineteen patients (36 electrodes) who underwent DBS with target correction from April 2017 to April 2018 were categorized into the corrected group. After operation, MRI/CT fusion was performed and ΔP was calculated. The electrode deviation degree was divided into 4 groups: ΔP≤1 mm, >1-2 mm、>2-3 mm and >3 mm. The first successful puncture was defined as follows: the electrode was implanted according to the target without adjustment. The success rate of the first puncture and the electrode deviation were compared between two groups. Results:The operations in two groups were successfully performed without serious complications such as disability or death. No brain infarction or hemorrhage was observed on postoperative CT. In the uncorrected group, the mean ΔP value of the left electrode was 1.6±0.9 mm, with X shifting medially by 0.1±0.9 mm, Y shifting posteriorly by 1.0±0.9 mm, and Z shifting upwards by 0.5±0.5 mm. The median ΔP value of the right electrode (upper and lower quartile) was 1.4 (1.2, 2.2) mm, with X shifting medially by 0.2±0.9 mm, Y shifting posteriorly by 1.0 (0.3, 1.5) mm, and Z shifting upwards by 0.4±0.5 mm. Target correction was conducted based on the deviation data as above: Y was adjusted by 1.0 mm anteriorly on both sides, and Z was adjusted by 0.5 mm downwards on both sides. The success rate of the first puncture in the corrected group was 94.4% (34/36), which was higher than that in uncorrected group (77.4%, 65/84). The difference was statistically significant ( χ2=5.082, P=0.024). In the corrected group, the ΔP value of the left electrode was smaller ( t=-3.507, P=0.001) than that in uncorrected group, while the ΔP value of the right electrode showed no statistical difference ( Z=-1.646, P=0.100). The deviation degree of bilateral electrodes in the corrected group were statistically different ( P<0.05) when compared with uncorrected group. Conclusion:The target correction method based on electrode deviation can improve the success rate of the first electrode puncture, reduce the deviation, and has clinical application value in accuracy improvement of DBS electrode implantation.