Clinical characteristics of intravenous nutrient solution leakage caused by percutaneous inserted central catheter in newborns: analysis of 16 cases

潘维伟,鲍文婷,朱巍巍,朴梅花
DOI: https://doi.org/10.3760/cma.j.cn113903-20200813-00802
2020-01-01
Abstract:Objective:To summarize the clinical characteristics of intravenous nutrient solution leakage caused by percutaneous inserted central catheter (PICC) in newborns.Methods:This study retrospectively analyzed the clinical characteristics of 16 newborns with PICC-induced intravenous nutrient solution leakage in the neonatal intensive care unit of Peking University Third Hospital from January 2015 to December 2019. Descriptive statistical analysis was used.Results:The total incidence of intravenous nutrient solution leakage caused by PICC in our hospital was 1.6% (16/1 012). Thirteen cases had the nutrient solution leakage in the pleural cavity, one in the pericardium and two in the cerebrospinal fluid. All of the 16 cases were preterm infants with an average gestational age of (30.5±0.5) weeks and an average birth weight of (1 314.4±62.1) g. The average age at the time of PICC implantation was (4.3±0.6) d. The average interval between catheter insertion and intravenous nutrient solution leakage was (7.3±2.0) d. The 13 patients with nutrient solution leakage in the pleural cavity all showed dyspnea, apnea and cyanosis. Besides these manifestations, bradycardia and decreased blood pressure were also found in one patient with the leakage in the pericardium. The two cases with the leakage in the cerebrospinal fluid mainly showed drowsiness and convulsions. The catheters were all inserted from the right vena basilica in the 14 cases with leakage in the pleural cavity and pericardium. Only five of them had the correct initial position of the catheter tip, while too deep initial implantation was noted in four cases with later adjustment on the same day, and the shift of the catheter tip position was noted in 10 cases when the leakage-related symptoms occurred. The catheters were inserted from the left saphenous vein in the two cases with nutrient solution leakage in the cerebrospinal fluid, who had an incorrect initial position of the catheter tip, and the catheter tip position shifted in both cases when the leakage occurred. The leakage-related symptoms of all 16 cases were alleviated rapidly after puncture drainage and PICC extubation with no recurrence.Conclusions:PICC-induced leakage of intravenous nutrient solution may be related to the shift of the catheter tip to non-central veins. Once leakage is diagnosed, PICC should be removed as soon as possible and the prognosis is good after drainage.
What problem does this paper attempt to address?