Clinical study on the application of peripherally inserted central catheters for critically ill neonates

Lou Xiaofang,Ma Meifang
DOI: https://doi.org/10.16821/j.cnki.hsjx.2007.23.004
2007-01-01
Abstract:Objective To study the catheter features such as catheter life,completion of therapy,complications and the correlation between the weight of infant and the length of catheter for critically ill neonates treated with PICC in NICU. Method A prospective study for all PICC inserted in the N1CU at the children's Hospital for four years.All clinical data of infant with PICC was collected and analyzed.Result 507 PICC were inserted among 502 infants.Providing nutrition,anti-infection treatment and applying vasoactive medication was the common reason for PICC insertion.Average catheter life was 15.53 days.Completion of therapy was achieved in 84.43%(423 cases).16.57%(84 cases) PICC were removed for complication.The rate of catheter-related bloodstream infection was 2.16/1000 catheter days.The proportion of non-central location of the catheter tip was significantly difference between the veins for insertion.The reference of catheter length for insertion was suggested according the infant weight in different vein.Conclusion PICC provides reliable and safe access for prolonged IV therapy in critically ill neonates and very low birth weight infants.The low incidence of complication with PICC makes them an attractive device for prolonged IV access.
What problem does this paper attempt to address?