Effects of TiSi coatings with different sintering temperature on corrosion resistance of dental CoCr alloy

Jie Zou,Bin Hu
DOI: https://doi.org/10.11752/j.kqcl.2015.03.07
2015-01-01
Abstract:Objective To investigate the effects of titanium-silicon (TiSi) coatings with different sintering temperature on corrosion resistance of dental soft CoCr alloy. Methods The commonly used soft CoCr alloy was cast into 18 specimens of size 10mm×10mm×1mm. These specimens were randomly divided into three groups (group A, B and C) (n=6). Then the specimens of group B and C were coated with TiSi on the surface by sol-gel method. The specimens of group B were sintered at 900℃, while the sintering temperature of group C specimens was 1000℃. The specimens of groupA, B and C were immersed in a lactic acid/NaCl solution at 37℃for 7 days. The method of weight loss was used to analyze the corrosion rate. The solutions were analyzed with ICP-AES to determain the release of elements. Results In the analysis of weight loss method data, there were no significantly differences in corrosion rate between group B and C (P>0.05). The corrosion rates of group B and C were lower than that of group A (P<0.05). The specimens of group A released significantly more ions (Co、Cr、Ni,and total ions) compared with the group B and group C specimens (P<0.05). The levels of Co、Cr、Si and total ions were higher in specimens of group B than that in group C (P<0.05). Conclusion TiSi coating can significant improve the corrosion resistance of soft CoCr alloy. The TiSi coating sintered at the temperature of 1000℃showed better corrosion performance than that of 900℃.
What problem does this paper attempt to address?