Concentration determination of voriconazole in human plasma by HPLC-MS/MS

Yang LIU,Ting-ting QIU,Chao ZHANG
DOI: https://doi.org/10.13699/j.cnki.1001-6821.2018.10.024
2018-01-01
Abstract:Objective To develop a method for concentration determination of voriconazole in human plasma in order to apply to clinics.Methods HPLC-MS/MS method was adopted.Using d3-voriconazole as internal standard,the determination was performed on Agilent Eclipse Plus C18 column with mobile phase consisted of acetonitrile-water (containing 0.01 mol · L-1 ammonium formate) 55∶45 at flow rate of 0.3 mL · min-1 and column temperature of 40 ℃.The electrospray ion source,positive ionizing pattern and multiple reaction monitoring were used;the mass transition ion-pairs of voriconazole and internal standard were m/z 350.2→m/z 281.1 and m/z 353.2→m/z 284.1.Results The linear standard concentration range of voriconazole was 50-1.0 ×104 ng · mL-1(r =0.9997),and the lower limit of quantitation was 50 ng · mL-1.Precision (RSD) of inter-day and intra-day were lower than 5%.Method recovery was higher than 95%,and extraction recovery was higher than 85%.The steady state trough voriconazole plasma concentrations of 17 patients with hematologic malignancy were 0.38-8.10 μg · mL-1 determined by this method,of which 3 patients were outside of the recommended range.Conclusion The established assay method in this study is rapid,accurate and sensitive,and can be applied for the therapeutic drug monitoring of voriconazole.
What problem does this paper attempt to address?