In Vitro Percutaneous Characteristics of Compound Lidocaine Cream

Yajing He,Xuexin Wu,Jie Zhou,Teng Shen,Jixiang He
2015-01-01
Abstract:Objective To investigate in vitro percutaneous characteristics of compound lidocaine cream, and the consistenty of in - vitrope-rcutaneous with the Emla cream. Methods The concentration of lidocaine and prilocaine in receptor fluid was quantified by HPLC. The in - vitro percutaneous experiments of compound lidocaine cream through rat abdomen skin were perfromed by modified Franz′s cell. Results There were good linear relationship between the peak area and concentration in the range of 0. 224 - 16. 8 μg / mL for lidocaine, andin the range of 0. 192 - 14. 414 μg / mL for prilocaine. The accuracy and precision could meet the require-ments. Percutaneous characteristicsof lidocaine and prilocaine accord with zero order kinetics equation. The flux oflidocainefor test and control creamis (274. 6 ± 30. 25) μg / (cm2·h)and (266. 4 ± 21. 56 )μg / (cm2·h), and the flux ofprilocainefor test and control creamis (314. 2 ± 31. 08)μg / (cm2 ·h) and (309. 4 ± 23. 08) μg / (cm2 ·h) There were no significant difference( P > 0. 05) by t - test statis-tics. Conclusion In vitropercutaneous patternare consistent for test and control compound lidocaine creams.
What problem does this paper attempt to address?