Risk Factors Related to Failure of Internal Fixation for Intertrochanteric Fracture

SHANG Song,JIANG Zan-li
DOI: https://doi.org/10.3969/j.issn.1671-6264.2013.03.016
2013-01-01
Abstract:Objective:To discuss the risk factors related to internal fixation for intertrochanteric fracture and investigate reliability of these factors as predictors for screw cutout.Methods:All patients with an intrertrochanteric fracture who were treated with a Gamma nail in our hospital from 2006 to 2010 were retrospectiverly evaluated.Results:Of the 249 patients,21(8.4%) failed with cutout of the lag screw.The mean tip-apex distance(TAD) of the patients with screw cutout was 35mm,compared with that of the patients who didn't have a cutout,and TAD measurement was reliable.The fracture reduction was also risk factor related to device cutout.Center and inferior position of the lag screw was protective against cutout.Conclusion:To decrease the risk of cutout,a good reduction is needed and the lag screw should be placed in the center or inferior part of the femur neck.The TAD is reliable predictor for cutout in intertrochanteric fracture.
What problem does this paper attempt to address?