Compare Insulin Sensitivity Index of Hyperinsulin Euglycemic Clamp with That of Mini-Model in Normal Population

陈宇红,毕宇芳,陈惠敏,张连珍,洪洁,胡仁明,赵咏桔,宁光
DOI: https://doi.org/10.3969/j.issn.1674-8115.2004.09.018
2004-01-01
Abstract:Objective To explore the relationship between mini-model technique and hyperinsulin euglycemic clamp in evaluating insulin sensitivity in healthy population. Methods All subjects have OGTT at first. If they are normal, then mini-model and clamp tests are carried out with an interval of one week. Calculate and compare the index of insulin sensitivity. Results The index of insulin sensitivity in mini-model was 6.81 ±4.27, while in clamp was 7. 84 ±2. 69; the relationship was r = 0. 742 (P0.001). Conclusion In normal population there is excellent relationship of insulin sensitivity index between mini-model and hyperinsulin euglycemic clamp.