Simultaneous determination of eleven preservatives in food by capillary column-gas chromatography after ultrasound-assisted dispersive liquid-liquid microextraction

NG YA,NG JIA,Yong XUE,Chengjun SUN
DOI: https://doi.org/10.3969/j.issn.1000-9760.2015.01.013
2015-01-01
Abstract:Objective To establish a method for simultaneous determination of eleven preservatives in foods by gas chromatography after ultrasound‐assisted dispersive liquid-liquid microextraction .Methods The target pre‐servatives in food samples were ultrasound‐assisted dispersive liquid-liquid microextracted ,and then they were separated with FFAP capillary column and detected with FID detector .Results Linear ranges of the method were between 0 .068 and 400μg/mL with correlation coefficients varying from 0 .9990 to 0 .9999 .Recoveries and rela‐tive standard deviations (RSDs)were in the range from 84% to 122% and from 3 .11% to 5 .83% ,respectively . The limitation of detection was in the range form 0 .026μg/ml to 0 .23μg/ml with enrichment factors ranging from 57 to 225 for all target compounds .Conclusion The method is simple ,efficient ,cheap ,eco‐friendly and is suitable for simultaneous determination of 11 preservatives in different foods .
What problem does this paper attempt to address?