AppIication of Improved CIosed EndotracheaI Suction on Patients With Severe Pneumonia

张楠,王志强,张岚,孙玫
DOI: https://doi.org/10.3969/j.issn.1007-9572.2015.11.026
2015-01-01
Chinese General Practice
Abstract:Objective To compare application effect of closed endotracheal suction method and improved closed endotracheal suction method of sputum suction on patients with severe pneumonia. Methods This study enrolled 17 patients with severe pneumonia who were admitted into the Tianjin Medical University General Hospital and received mechanical ventilation for more than 24 h from January 2013 to January 2014 and assigned them into observation group(n=9)and control group(n=8) according to odd and even number in admission order. Sputum suction was conducted when patients needed. Control group was treated with general sputum suction method, and observation group was treated with the closed endotracheal suction method improved by trials. During mechanical ventilation period,condition of first suction of each subject in each day was recorded. Indicators of safety were examined,including instant heart rate( HR) and mean arterial pressure( MAP),oxygen saturation ( SpO2 ) before and after suction,tolerability and damage of mucous membrane in airway;indicators of effect were examined, including amount of single sputum suction,the total amount and times of sputum suction in 24 h and thorough sputum sanction;indicators of prognosis were examined,including length of trachea cannula and length of stay in ICU. ResuIts Conditions of 121 cases of suction were recorded,57 for control group and 64 for observation group. There were no significant differences between the two groups in the instant HR and MAP, SpO2 before and after suction, tolerability and incidence of mucous membrane bleeding(P﹥0. 05). There were no significant differences between the two groups in the total amount of sputum suction in 24 h and score in coarse rales(P﹥0. 05). Observation group was higher than control group in amount of single sputum suction and lower than control group in the total times of sputum suction in 24 h(P﹤0. 05). There were no significant differences between the two groups in length of trachea cannula and length of stay in ICU(P﹥0. 05). ConcIusion The improved method of closed endotracheal suction has a safe and steady effect. It reduces work amount in clinical nursing,improves work efficiency of nurses and also reduces the fear of patients for suction operation. This method can lead to the satisfaction of nurses and patients. Therefore,its clinical application should be promoted.
What problem does this paper attempt to address?