Effect of ventilation with high levels of PEEP and lower-tidal volume on the hemodynamics in patients with normal respiratory function
曾琼,孟勇,朱四海,惠康丽,张转,赵新民,杨建军,周志强,段满林,徐建国
2009-01-01
Abstract:Objective To investigate the hemodynamic effects of lung-protective ventilation strategy with lower-tidal volume and different levels of PEEP in patients with normal respiratory function. Methods One hundred and two patients, ASA Ⅰ or Ⅱ, undergoing otolaryngological surgery. Patients were randomly assigned to six groups (n=17). P0,P5,P10,P15 and P20 five study groups, with 0,5,10,15 and 20cmH2O PEEP level, specifically, were ventilated with lung-protective ventilation strategy (VT=5ml/kg). The control group was ventilated with conventional ventilation strategy (VT=10ml/kg).The changes of hemodynamics after 30min were recorded. Results Compared with control group and at T1, ACI increased significantly in P5,P10 and P15 groups and decreased significantly in P20 group, CI,LCWI and MAP decreased significantly in P20 group at T2 (P<0.05). TFC decreased significantly in P10,P15 and P20 groups at T2 than that at T1 (P<0.05).Conclusion When lung-protective ventilation strategy was applied in patients with normal respiratory function, it caused no significant effect when PEEP at 0,5cmH2O . When PEEP at 10 or 15cmH2O,the reduction in TFC and increase in ACI showed potential impact on the hemodymamics. Serious effect in the hemodynamics was observed when PEEP at 20cmH2O.