Application value of bedside real-time ultrasonography in umbilical venous catheters

樊婷婷,潘家华,陈名武,王琳,韩明华
DOI: https://doi.org/10.3969/j.issn.1000-0399.2018.03.013
2018-01-01
Abstract:Objective To explore the application value of bedside real-time ultrasonography in umbilical venous catheter(UVC). Methods Fifty-eight cases requiring UVC from November 2016 to April 2017,who were hospitalized in NICU,Anhui provincial hospital, wererecruited in this prospective,self control study.The relationship between the actual position catheter and its corresponding X position was analyzed.The difference between two ways of estimating catheter location,and the difference between actual depth and prediction were com-pared.Results Catheter tip position in the atrium and the junction of inferior vena cava with the right atrium(target area)was T5-T9,T7-T9 respectively.The way of checking tip position between ultrasound and X-ray was statistically significant(χ2=4.35, P=0.04).The difference between actual insert depth and prediction depth was statistically significant(P<0.05).Conclusion Insertion of the UVC with bedside real-time ultrasound,which provides direct visualization,is more adequate and can be performed by the neonatologists in charge of the procedure.