Homemade Pneumatic Microdrop-on-demand System and Impacts of Jetting Process on Cell Viability

Zhihai WANG,Zhixiong NIE,Meng WANG,Shuai TONG,Xi CHEN,Jingang GUI
DOI: https://doi.org/10.11936/bjutxb2016120026
2017-01-01
Abstract:To print cells and maintain high cell viability, a pneumatic droplet-on-demand ( DOD) system was designed. The key components of the system included a chamber for liquid sample, a tiny orifice of 100μm. The chamber was connected to a Nitrogen gas tank with a high speed solenoid valve, and to the ambiance with a venting tube. A photographic system was used to evaluate the uniformity and consistency of the DOD system. A pressure pulse was created within the chamber via controlling the solenoid valve. The liquid was pushed out through the nozzle, generating a droplet. The gas was then released through the venting tube, recovering the system back to equilibrium. As confirmed by the photographic system, stable generation of single droplet was realized, with a generation frequency of 20 Hz, and with droplet diameter around 200μm. Finally, jetting of human peripheral blood lymphocytes ( PBL) and buffer was tested. Based on flow cytometry studies, the impacts of the micro-drop generation process on viability of the human PBLs were found to be negligible.
What problem does this paper attempt to address?