Experimental study of industrial low nitrogen porous media burner

Xue-song WU,Le-ming CHENG,Ke YAN,Wei-guo ZHANG
DOI: https://doi.org/10.3785/j.issn.1008-973X.2018.11.012
2018-01-01
Abstract:A combustion test of porous media burner was conducted to investigate the stability limits of low nitrogen burner. Characteristics of nitrogen oxide (NOx) and carbon monoxide (CO) emissions of the burner at varied burner powers from 50 kWto 100 kW and varied equivalence ratios from 0.6 to 1.0 were presented. The influence of porous media diameter on the combustion production was also studied. Results showed that the stable operating range extended and shifted to larger values while the equivalence ratio increased, and the upper limit increased greater than the inferior limit. NO was the main component of oxynitride when natural gas combusted in the porous media burner. The NOx emission increased with the burner power and the equivalence ration. The maximum NOx emission of the burner was below 30 mg/m3 for all operating conditions. The industrial porous burner has low NOx emission characteristics. CO concentration increased after a decrease with the rise of equivalence ratio, and it was below 56 mg/m3 when the equivalence ratio was smaller than 0.9. To achieve low NOx and CO emissions at the same time, the equivalence ratio should be controlled between 0.7 and 0.8. There is no significant changes in NOx and CO emissions for the two porous media diameters.
What problem does this paper attempt to address?