Removal of NOx by ozone oxidation from flue gas of 60 000 m3/h carbon black drying furnace of rubber plant

Yan-qun ZHU,Ye YANG,Jian-peng HUANG,Fa-wei LIN,Qiang MA,Chao-qun XU,Zhi-hua WANG,Ke-fa CEN
DOI: https://doi.org/10.3785/j.issn.1008-973X.2016.10.005
2016-01-01
Abstract:The observation of the removal of NOx by ozone oxidation from flue gas was conducted at a 60 000 m3/h carbon black drying furnace with multi‐pollution absorption treatment by ozone oxidation in Hangzhou in order to explore the effect factors of pollutant removal by ozone oxidation in industrial program .Results showed that when the O3/NOx mole ratio was above 0 .7 ,the NOx removal efficiency was enhanced with low temperature of the flue gas in front of the tower and long residence time of the flue gas in spray tower .When the O3/NOx mole ratio was 0 .73 ,the NOx removal efficiency was enhanced with the pH of solution in spray tower .While the O3/NOx mole ratio was 1 .23 ,the pH of solution almost had no effect on the NOx removal efficiency .Considering that temperature of the flue gas is the dominant factor of the NOx removal efficiency ,installing a steam water heat exchanger to reduce gas temperature is an effective and available method in industrial program .
What problem does this paper attempt to address?