Dynamic Analysis of an Asymmetry Double-Tower Connecting Building

邬喆华,孙炳楠,楼文娟,唐锦春,周樑
DOI: https://doi.org/10.3785/j.issn.1008-973x.2003.05.014
2003-01-01
Abstract:According to a construction project of an asymmetric double- tower connecting tall building,a three- dimension calculating model considering the in- plane elastic deformation of floor was built. The high- precision finite element method with beam and shell elements was used. Mode- frequency analysis with Block Lanczos solution and single- point acceleration response spectrum analysis were applied to study the structural dynamic performance. The first 20 periods,modal shapes,mode coefficients and effective mass fractions of the building with the connection were calculated and compared with those of a building without the connection and single- tower buildings. It was shown that the connection reinforces the whole structure. The modes contained not only the modes component of two single- tower buildings respectively, but also the contribution of the connection and the podium. Analysis of the seismic resistance capacity of a double tower connecting building shows that number of effective vibration modes of a building with the connection is less than that of a building without the connection. Also,the connection enlarges the non- uniform distribution of structural stiffness along the height. The rate of vibration shape change is large and the internal forces may be increased at the intersection of the connection. The twist mode shape occurred in advance and the twist component in every mode is increased because of the structural asymmetry.
What problem does this paper attempt to address?