An Optimal Automatic Control of Plate-and-Frame Filter Press for Sludge Dewatering System

Cheng ZHU,Jun YUAN,Jin SHI,Jian HE,Ping ZHOU
DOI: https://doi.org/10.3969/j.issn.1001-4543.2014.02.007
2014-01-01
Abstract:It is difficult to detect cake moisture content on-line in plate-and-frame filter press (PFP), so the automatic shutdown control of a plate-and-frame filter press system is generally designed and operated by experience. The rate of exhaust water was chosen as an on-line monitoring indicator to design an automatic control system for a PFP on the basis of on-site monitoring data. It is shown that the new-built system operates automatically and can save more than 15%of the compressed air volume, which indicates that the automatic control system contributes to a better dewatering system.
What problem does this paper attempt to address?