ANALYSIS OF ELEMENTS CONTENT ON ADHESIVE JOINT SURFACE AND INTERFACE WITH ENERGY DISPERSIVE X-RAY SPECTROSCOPY

WANG Chao,LI Zichen,DU Fusheng,HUANG Yudong
DOI: https://doi.org/10.3321/j.issn:1000-3851.2005.05.010
2005-01-01
Abstract:Energy dispersive X-ray spectroscopy(EDX) is a kind of analysis method used in researching the adhesive joint and polymer composite surface and interface characters.The changes of the adhesive/carbon-carbon composite joint surface and interface at different temperatures were researched by EDX.The results indicate that carbon element content on C-C composite surface in Z direction is less than that in X and Y directions from room temperature to 900℃,which was decided by the characters of C-C composite.The break form of the adhesive/carbon-carbon composite joint is changed from C-C composite break at room temperature into adhesive break at higher than 200℃.The changes of carbon,oxygen and silicon elements content on the adhesive and C-C composites surface indicate that the heat decomposition speed of the adhesive is almost the same as that of C-C composite under 550℃,but above 550℃ the adhesive decomposition speed is faster than that of C-C composites.