Optimal Performance Research of Frost-free Air-cooled Refrigerator with Microchannel Condenser

Chengquan Zhang,Junye Shi,Jiangping Chen
DOI: https://doi.org/10.3969/j.issn.0253-4339.2017.03.043
2017-01-01
Abstract:With implementation of the Maximum Allowable Values of The Energy Consumption And Energy Efficiency Grade For House-hold Refrigerators(GB 12021. 2—2015), this study experimentally investigated the application of four typical kinds of microchannel heat exchangers ( MPE) on domestic refrigerator system. The investigation was conducted from component to system, and heat exchanger per-formance was compared with original condenser. The results show that for the best MPE sample, the heat transfer performance can in-crease by 13%, the air-side pressure drop is only 28%, and the refrigerant-side pressure drop is only 54%. The best MPE sample was introduced into a refrigerator system, and the charge of refrigerant for the system was optimized. The optimized system energy consumption was tested under national standard GB/T8059—2016. The results show that the energy consumption of the new system was 2. 8% lower than the original under a test condition of 25 ℃, and the calculated energy consumption based on the new national standard was 2. 6%lower than the original. This can meet the first-class requirements of the new national standard.
What problem does this paper attempt to address?