Energy Consumption Analysis of Quasi-isothermal Compression Method for Micron-sized Water Spray

WANG Jia,JIA Guan-wei,XU Wei-qing,CAI Mao-lin
DOI: https://doi.org/10.11832/j.issn.1000-4858.2018.06.021
2018-01-01
Abstract:Since most compressed air systems are based on adiabatic compression,about half of the electricity is converted into heat and dissipated.As the temperature of air rises during compression,more energy is converted into heat and efficiency of compression is reduced.Micrometer (19 ~ 38 μm) water spray is mixed with the compressed air to absorb air heat and reduce compressed air temperature.Under conditions of micro-scale water mist cooling and compression generated by different nozzle effective diameters,the characteristics of air temperature,pressure,compression work and compression efficiency are simulated and analyzed.The critical energy and extreme energy consumption lines of quasi-isothermal compression water mist are calculated and optimized.It provides an effective criterion for design of water mist cooling quasi-isothermal compression system.
What problem does this paper attempt to address?