Application of Multi-pass Circulating Fluidized Bed in Integrated Energy Service

HAN Feng,CONG Kunlin,LI Qinghai,ZHANG Yanguo,YAN Jiaoping,HU Feng
DOI: https://doi.org/10.12096/j.2096-4528.pgt.19171
2020-01-01
Abstract:Park level clean heating is an urgent problem to be solved in integrated energy service. The multi-pass circulating fluidized bed technology adopts a three-stage furnace structure to form a two-stage material circulation in the furnace, which solves the problem of miniaturization of traditional circulating fluidized bed boilers. The industrial practice has proved that the multi-pass circulating fluidized bed boiler can use biomass, industrial solid waste, coal and other fuels. The thermal efficiencies of various fuels reach 88%~92%, and the emissions of the pollutants meet the required permissible effluent concentrations of the national standards and local standards. The multi-pass circulating fluidized bed technology has the advantages of decentralized energy utilization and simultaneous application of multiple fuels, which can be effectively applied to park level integrated energy service.
What problem does this paper attempt to address?