Development and experimental investigation on forced-air precooling device with alternating ventilation mode

Yuping Gao,Shuangquan Shao,Changqing Tian,Yanjie Liu
DOI: https://doi.org/10.3969/j.issn.1009-8402.2017.12.018
2017-01-01
Abstract:In the traditional forced-air precooling device,the temperature in the precooling process is not even for the fruits and vegetables along the airflow direction.In order to improve the uniformity,one novel forced-air precooling with alternating ventilation mode is put forward.Then,a forced-air precooling device with alternating ventilation mode is developed.The fresh tomatoes are used to investigate the effect of the switch number on the forced-air precooling process with alternating ventilation mode,which is also compared with the precooling process with the traditional unidirectional ventilation mode.The results show that using the traditional unidirectional ventilation mode,the temperature in the precooling process is quite uneven for the tomatoes along the airflow direction.After the ventilation direction is changed,the uneven temperature can be reduced,the most disadvantageous position is transposed from the end-position to the middle-position.Besides,the bigger the switch number,the more even the precooling process.In addition,the weight loss is increased for the tomatoes along the airflow direction using the traditional unidirectional ventilation mode.However,the weight loss will tend to be consistent for the tomatoes of different positions along the airflow direction after using the alternating ventilation mode.
What problem does this paper attempt to address?