Research on Dust Control with Wall Attachment Fan Drum in the Underground Heading Face

Lu Xinxiao,Huo Yujia,Han Yu,Xue,Zhou Quantao
DOI: https://doi.org/10.19606/j.cnki.jmst.2020.04.006
2020-01-01
Abstract:The heading face is the main dust production region in underground coal mines. Through reducing the gas velocity and forming an air curtain, the dust can be controlled effectively. The dust control effect of wall attachment fan drum in the middle and small sections is investigated in this paper based on the gas-dust coupled physical model. The study results show that high concentration dust is controlled in a narrow space of the heading face by the wall attachment fan drum. The highest dust concentration is as high as 5.65 of the conventional fan drum. The dust control efficiency is highest at the fan drum exit, which decline from above to below. The change law of dust control efficiency is opposite at the return side. The dust reentrainment and vortex region are improved when the distance between the fan drum and heading face is 3~5 m, at which the dust control effect is best and the dust concentration is less than 50 mg/m3 in the tunneling roadway. Field practice shows that the dust suppression efficiency of dedusting fan increases by 29.4% at the driver position and 36.1% behind the return side when the wall attachment fan drum is additionally used in the middle-small heading face. The remarkable dust suppression effect indicates that the wall attachment fan drum is efficient in controlling the dust diffusion and increasing the efficiency of dust technology.
What problem does this paper attempt to address?