Separating of Manganese From Magnesium in Organic Phase by Sulfuric Acid Washing

Biao DENG,Xueping LIU,Jingyan JIANG,Shijun SU,Sanglan DING,Weiyi SUN
DOI: https://doi.org/10.13355/j.cnki.sfyj.2018.02.008
2018-01-01
Abstract:In the process of recovery manganese from electrolytic manganese anode solution by P204 solvent extraction,some magnesium ions are also extracted into organic phase with manganese ions, w hich is unfavorable to strip and recover manganese.Separating magnesium ions from organic phase by washing using sulfuric acid were researched.For the organic solution with manganese ions and magnesium ions concentration of 8.67 g/L and 0.799 g/L,the effects of washing time,standing time, sulfuric acid concentrate,ratio of organic phase volume to water phase volume(Vo:Va)and washing stage on washing of magnesium ions were examined.The results show that under the conditions of temperature of 35 ℃,sulfuric acid concentration of 0.03 mol/L,Vo:Vaof 1:3,washing time of 10 min,standing time of 40 min and two stage washing,magnesium ions concentration in organic phase can decreased to 6.85 mg/L.
What problem does this paper attempt to address?