Excitation Frequency Choice and Sensitivity Analysis in the Inspection of Pipe with Ultrasonic Guided Waves

De-an TA,Wei-qi WANG,Yuan-yuan WANG,Jian-guo YU,Zhenqing LIU
DOI: https://doi.org/10.3969/j.issn.1000-6656.2005.02.008
2005-01-01
Abstract:The heat-exchanger pipes could be inspected by ultrasonic longitudinal guided waves. Firstly the optimal testing mode L(0,2) was selected according to the dispersion curves of guided waves, then the frequency-thickness product was chosen according to the displacement, stress and total energy density(TED) amplitude distributions. Finally, the sensitivity of testing was analyzed in the experiment. Results showed that the defects in pipes could be detected distinctly even if the wavelength of L(0,2) mode was 10 times longer than the defect size.
What problem does this paper attempt to address?