Quantitative nondestructive evaluation of multilayer thin films based on two-dimensional optical coherence tomography

Dan-yang CHEN,Jun-hai TONG,Shun-cong ZHONG,Qiu-kun ZHANG,Jie-wen LIN,Xi-bin FU
DOI: https://doi.org/10.3969/j.issn.1001-4551.2017.08.006
2017-01-01
Abstract:In order to achieve fast accurate thickness measurement and nondestructive evaluation of multilayer thin films, a two-dimensional optical coherence tomography ( OCT) was developed. The developed system did not need to point-by-point scan the sample and therefore, the problem of low imaging efficiency was avoided by point by point scanning. In addition, the theory of removing OCT conjugate mirror image was presented;also, five-step phase-shifting interferometry method was employed the system to remove the effect of OCT conjugate mirror im-age and finally to avoid image aliasing. A PZT actuator was used to drive the reference mirror to achieve the five phase. By using the system, the internal structure of mobile toughened glass film was accurately measured, including toughened glass, the first electrostatic glue, explo-sion-proof film and the second electrostatic glue. Experimental results demonstrated that the home-made system had high-accuracy and high-speed imaging performance for the measurement of multilayer thin films. It could be recommended for non-destructive evaluation of multilayer thin films.
What problem does this paper attempt to address?