Unbalanced Steam Force Analysis Between Single Valve and Sequence Valve Switching for Steam Turbines

Peng WU,Qian-min LI,Yi-hui BAI,Rui-feng ZHANG,Wen-tao PANG,Zhu WANG,De-ren SHENG
DOI: https://doi.org/10.3969/j.issn.1001-5884.2018.03.017
2018-01-01
Abstract:Steam turbine change from partial-arc admission to full-arc admission during switching from single valve to sequence valve, causing unbalance force on the governing stage impeller, increased load on the bearing. High bearing temperature and excessive vibration problem may also occur in this situation. In order to solve the high temperature problem of bearing pad during switching from single valve to sequence valve, the force model of governing stage under partial-arc admission condition has been analyzed, the force condition of high pressure cylinder bearing under different switching modes has been calculated and compared. The optimization scheme has been proved superior both from qualitative and quantitative perspectives. This result is also verified by previous steam distribution tests. This study has proved appropriate switching method can effectively reduce unbalanced force and achieve safety switching.
What problem does this paper attempt to address?