Numerical Simulation for the Impact of Structural Parameters on Heat Transfer in the Tube-side Flow of Spiral-wound LNG Heat Exchanger

Shu-lei LI,Lai-yun LU,Jie CHEN,Wei-hua CAI,Yi-qiang JIANG,Hao-chun ZHANG
DOI: https://doi.org/10.3969/j.issn.1002-6339.2017.06.004
2017-01-01
Abstract:The spiral-wound LNG heat exchanger is the first choice for the main cryogenic heat exchang-er in the large-scale natural gas liquefaction plant since it not only has a compact structure and can work for a variety of refrigerants' heat transfer,but also it can work at high operating pressure and its thermal expansion can be self-compensation.In the design calculations,the structures and size of geometric must be defined in order to meet the heat load under certain conditions.In this paper,a simple CFD model of tube-side flow and heat transfer in spiral-wound LNG heat exchanger verified by experimental data in the existing literatures was introduced and the simulation of tube-side flow for methane under different structural parameters were presented.By analysis of orthogonal test,a better structural parameters of the tube-side were obtained.Furthermore,it provided a reference for the design of the spiral-wound LNG heat exchanger.
What problem does this paper attempt to address?